DIGITAL HYDROTEST LOGGER

Barton Chart Digital

A digital hydrotest pressure logger inspired by Barton chart recorder, designed for pressure trend monitoring, holding time logging, leak/drop detection, PASS/FAIL result, CSV export, and automatic PDF report generation.

HYDROTEST LOGGER PASS
PRESSURE 248.6
HOLDING 02:15
DROP 0.8%
WHY DIGITAL

Modern Hydrotest Monitoring

Barton Chart Digital helps replace manual recording with a digital dashboard, data logger, automatic result calculation, and exportable report for pressure testing activity.

MANUAL CHART ISSUE

Hard to Read Chart

Manual chart reading can be difficult, inconsistent, and time-consuming during hydrotest documentation.

REPORTING

Slow Report Preparation

Digital data helps generate pressure trend, event log, CSV export, and PDF report more quickly.

TRACEABILITY

Better Test Record

Keep pressure data, holding time, alarm, event, operator note, and result history in digital format.

FEATURES

Key Features

Designed for hydrotest, pipeline pressure test, vessel test, and field pressure monitoring activity.

PRESSURE

Pressure Trend

Monitor real-time pressure value and pressure trend during pressurizing and holding period.

  • 4–20 mA transmitter input
  • Pressure unit display
  • Trend visualization
HOLDING

Holding Time Logger

Record holding test duration and elapsed time automatically once the test condition is started.

  • Start / Stop / Reset
  • Elapsed time tracking
  • 24-hour test concept
RESULT

PASS / FAIL Result

Compare pressure drop against allowable drop criteria to support hydrotest result decision.

  • Target pressure setting
  • Allowable drop setting
  • Automatic result label
REPORT

PDF & CSV Export

Export test data for documentation, review, client submission, and project record.

  • PDF report concept
  • CSV data export
  • Event logger
WORKFLOW

Hydrotest Workflow

A simple workflow from sensor input to final test report.

1

Connect Sensor

Connect pressure transmitter signal to the data logger system.

2

Set Parameter

Set target pressure, test duration, pressure unit, and allowable drop.

3

Start Test

Start logging during pressurizing and holding test activity.

4

Monitor Result

Monitor pressure trend, alarm, event, and drop calculation.

5

Export Report

Generate PDF report and CSV file for documentation.

SPECIFICATION

Concept Specification

Specification can be customized based on hydrotest procedure, pressure range, sensor type, report format, and customer requirements.

Application Hydrotest monitoring, pipeline pressure test, pressure holding test, and field pressure logging
Input Signal 4–20 mA pressure transmitter input concept
Pressure Range Configurable LRV / URV, scalable based on transmitter range
Display Web dashboard, trend chart, alarm status, elapsed time, result status, and event log
Data Export CSV export and PDF hydrotest report concept
Connectivity Local network / web dashboard concept, can be customized for IoT monitoring
Customization Report format, signature field, pressure unit, alarm setting, and acceptance criteria can be adjusted

Need Barton Chart Digital Demo?

Contact Java Instrument Control Solusi to discuss hydrotest monitoring, pressure logger, report format, sensor input, and digital dashboard requirements.

💬